服務熱線電話
400-6188-756
碳氫清洗設備環(huán)境對于環(huán)境的使用要求!
來源:http://www.qduv.cn/ 時間: 2022-12-03 瀏覽次數(shù): 0
1.使用溫度不得超過40。
1. The operating temperature shall not exceed 40.
2.設備周圍濕度75%,不能太干。
2. The humidity around the equipment shall be 75%, and it shall not be too dry.
3.保持清潔室的空氣流通。(如果沒有空氣流通,通風系統(tǒng)每小時2萬立方米以上)
3. Keep the clean room ventilated. (If there is no air circulation, the ventilation system is more than 20000 cubic meters per hour)
4.碳氫化合物清洗機設備的排氣系統(tǒng)需要與室外連接。(排氣系統(tǒng)每小時2200立方米)
4. The exhaust system of hydrocarbon washer equipment needs to be connected to the outdoor. (2200 m3/h for exhaust system)
5.防爆照明燈應設置在設備布置范圍內(nèi)5.防爆電器。
5. Explosion proof lamps shall be set within the equipment layout. 5. Explosion proof electrical appliances.
6.設備嚴禁在陽光下爆炸,以免溫度升高,造成危險。
6. It is strictly forbidden to explode the equipment in the sun to avoid the safety hazard caused by temperature rise.
7.嚴禁在設備周圍5米內(nèi)燃放煙花.引火作業(yè)及粉塵。
7. Fireworks, ignition and dust are prohibited within 5 meters around the equipment.
8.用戶應直接離設備1(1)直接安裝電源(設備電源箱).空氣保護開關(guān)安裝在距離地面1.6米以上的地方。(設備檢修時切斷電源方便使用)如果有專門的主電源柜,現(xiàn)場必須距離設備5米。
8. The user shall directly install the power supply (equipment power box) 1 (1) away from the equipment. The air protection switch shall be installed 1.6 meters above the ground. (Cut off the power supply for easy use during equipment maintenance) If there is a special main power cabinet, the site must be 5 meters away from the equipment.
9.冷水機組應設置在清洗設備旁邊3-5米之間,并安裝排氣管裝置。(排氣量為每小時2萬立方米)
9. The chiller shall be set 3-5 meters away from the cleaning equipment, and the exhaust pipe device shall be installed. (The air displacement is 20000 cubic meters per hour)
相關(guān)產(chǎn)品
相關(guān)文章
-
通過式噴淋清洗機:為什么洗不干凈? 2024-11-22
-
高壓去毛刺清洗機:遇見故障莫慌張,依次排查按文章 2024-11-21
-
單工位旋轉(zhuǎn)噴淋清洗機:為什么與其他清洗機相比要選擇它? 2024-11-20
-
碳氫清洗機:為何碳氫清洗機會清洗的干凈 2024-11-18
-
超聲波清洗機的弊端 2024-11-16
-
高壓去毛刺清洗機的保養(yǎng)秘訣 2024-11-14
-
超聲波清洗機的工作原理 2024-11-12
-
了解噴淋清洗機的特點和應用 2024-11-07
-
如何使用碳氫清洗機? 2024-11-05
-
污水低溫蒸發(fā)設備的結(jié)構(gòu)運行特點有哪些? 2024-10-31